English | Ivoclar Programat P100 Manual

: It is recommended to check the temperature regularly with an independent system and recalibrate as necessary to account for contamination in the firing chamber.

To ensure your Programat P100 lasts 15+ years, follow this schedule extracted from the maintenance section: ivoclar programat p100 manual english

| Error Code | Description | Manual Reference | Solution | |------------|-------------|------------------|----------| | E-01 | Thermocouple open circuit | Sec. 8.2 | Check connection; replace TC | | E-07 | Vacuum not reaching setpoint | Sec. 8.5 | Inspect pump, hoses, or door seal | | E-12 | Heating rate too slow | Sec. 8.7 | Check heating elements for wear | | --- | Furnace does not start | Sec. 5.1 | Verify power switch and fuse | : It is recommended to check the temperature