Long press the [SET] button to enter the function selection mode.
Relay closes when the voltage is either below the lower limit or above the upper limit. 4. Parameter Programming (Setting Mode) Enter Settings: Long press to enter the selection interface (displays "P-0"). Select Parameter: Short press to cycle through parameters P-0 to P-5 Function Selection (F-01 to F-05). Lower Limit Voltage (0.0V to 99.9V). Upper Limit Voltage (0.0V to 99.9V). Voltage Calibration (match display to a known voltmeter). Delay for Relay Pull-in (0.0 to 99.9s). Delay for Relay Disconnect (0.0 to 99.9s). Adjust Values: buttons to change values. Use to switch between digits (flashing). Save & Exit: Long press to save all settings and return to normal operation. 5. Special Features dvb01 user manual
Available in versions for DC 5V, 12V, or 24V power supplies. Load Capacity: DC: 0–30V / 10A. AC: 0–250V / 10A. Long press the [SET] button to enter the